Capacity class from series CDK-DR-H-10

CD54K-DR-H-10

CDK-DR-H ·Compact Steam Generator

Steam Output
216.0kg/h
Pressure max.
10.0bar(g)
Heating Output
3× 54kW
Voltage
400V

The CD54K-DR-H-10 is an electrically heated steam generator from the DINO CDK-DR-H-10 series in CDK-DR-H design with 216 kg/h steam output, up to 10 bar(g) working pressure and 3× 54 kW heating output. Designed and configured by DINO Dampferzeuger GmbH in Bremen, tested to PED 2014/68/EU. Made in Germany since 1960.

Equipment

2 variants

Purchase or rental *

Please choose purchase or rental.

Options (0 of 4)

Technical data — CD54K-DR-H-10

All values are reference figures. We configure the CD54K-DR-H-10 individually for your process — heating output, pressure stage, connection values and accessories.

Steam Output

216.0 kg/h

Working pressure max.

10.0 bar(g)

Heating Output

3× 54 kW

Weight

970 kg

Performance
Steam Output (kg/h)
216.0
Heat output (kcal/h)
143,486.21
Working pressure min. (bar(g))
1.0
Working pressure max. (bar(g))
10.0
Max. operating pressure (bar(g))
11.5
Max. Steam Temperature (°C)
184
Electrical ratings
Operating Voltage (V)
400
Frequency (Hz)
50
Phases
3+PE
Heating Output (kW)
3× 54.0
Heating element arrangement
3x
Total Connected Load (kW)
168.0
Control voltage (V DC)
24
Total rated current (A)
3× 81
Fusing (site-supplied) (A)
3× 100
Minimum cross-section (mm²)
3x 4x35,0
Mechanical Connections
Steam Line
Flange DN20
Water Inlet
External thread R1/2"
Blowdown valve
Flange DN25
Safety valve
Flange DN32
Condensate safety valve
Internal thread 1/2"
Condensate steam line
Internal thread 1/2"
Tank overflow / drain
External thread G3/4"
Tank condensate inlet
Internal thread G1/2"
Flash steam
Internal thread G3/4"
Compressed air
Compressed air min. (bar(g))
5.5
Compressed air max. (bar(g))
10
Dimensions & Emissions
Width (mm)
2,400
Height (mm)
1,850
Length (mm)
1,000
Weight (kg)
970
Sound Pressure Level (dB(A))
63

Conformity & standards

  • CE marking
  • PED 2014/68/EU
  • EMC Directive 2014/30/EU
  • Low Voltage Directive 2014/35/EU

Frequently asked questions about CD54K-DR-H-10

What is the steam output of the CD54K-DR-H-10?

The CD54K-DR-H-10 delivers 216 kg/h of saturated steam at a max. working pressure of 10 bar(g).

What is the heating output of the CD54K-DR-H-10?

3× 54 kW of electrical heating output, rated for 400 V operating voltage.

Is a data sheet available for the CD54K-DR-H-10?

Yes. The data sheet for CD54K-DR-H-10 (PDF) is linked directly in the hero section; the series data sheet with all capacity classes is available on the series page.

How quickly is the CD54K-DR-H-10 available?

Delivery time on order, typically 6–10 weeks ex works Bremen. Rental units are often available at short notice — please ask us directly for current availability.

Non-binding consultation on CD54K-DR-H-10

Our engineering team in Bremen configures the CD54K-DR-H-10 to match your process — output, pressure, connection values and accessories.