Skip to content

1 / 5

Electric Steam Generators

Model

CDK-DR-H-10

CDK-DR-H — Compact Steam Generator from DINO, up to 10.0 bar(g) working pressure, 144.0–288.0 kg/h steam output. Electrically heated, Made in Germany.

Capacity class

5 variants

→ swipe for more classes

Steam output
kg/h
Pressure max.
bar(g)
Heating output
kW

Equipment

2 variants

Purchase or rental *

Please choose purchase or rental.

Options (0 of 4)

Technical data

This series is available in 5 capacity stages, depending on the required steam volume or available connected load.

Series data sheet (PDF, all 5 capacity classes)
CD36K-DR-H-10 active
  • Steam output 144.0 kg/h
  • Pressure max. 10.0 bar(g)
  • Heating output 3× 36 kW

Performance

Steam output(kg/h)
144.0
Heat output(kcal/h)
95,657
Working pressure min.(bar(g))
1.0
Working pressure max.(bar(g))
10.0
Max. operating pressure(bar(g))
11.5
Max. steam temperature(°C)
184

Electrical ratings

Operating voltage(V)
400
Frequency(Hz)
50
Phases
3+PE
Heating output(kW)
3× 36.0
Heating element arrangement
3x
Total connected load(kW)
114.0
Control voltage(V DC)
24
Total rated current(A)
3× 55
Fusing (site-supplied)(A)
3× 63
Minimum cross-section(mm²)
3x 4x25,0

Mechanical connections

Steam line
Flange DN15
Water inlet
External thread R1/2"
Blowdown valve
Flange DN25
Safety valve
Flange DN32
Condensate safety valve
Internal thread 1/2"
Condensate steam line
Internal thread 1/2"
Tank overflow / drain
External thread G3/4"
Tank condensate inlet
Internal thread G1/2"
Flash steam
Internal thread G3/4"

Compressed air

Compressed air min.(bar(g))
5.5
Compressed air max.(bar(g))
10.0

Dimensions & emissions

Width(mm)
2,400
Height(mm)
1,850
Length(mm)
1,000
Weight(kg)
970
Sound pressure level(dB(A))
63
CD36K-DR-H-10 detail page Data sheet PDF
CD45K-DR-H-10
  • Steam output 180.0 kg/h
  • Pressure max. 10.0 bar(g)
  • Heating output 3× 45 kW

Performance

Steam output(kg/h)
180.0
Heat output(kcal/h)
119,572
Working pressure min.(bar(g))
1.0
Working pressure max.(bar(g))
10.0
Max. operating pressure(bar(g))
11.5
Max. steam temperature(°C)
184

Electrical ratings

Operating voltage(V)
400
Frequency(Hz)
50
Phases
3+PE
Heating output(kW)
3× 45.0
Heating element arrangement
3x
Total connected load(kW)
141.0
Control voltage(V DC)
24
Total rated current(A)
3× 68
Fusing (site-supplied)(A)
3× 80
Minimum cross-section(mm²)
3x 4x35,0

Mechanical connections

Steam line
Flange DN20
Water inlet
External thread R1/2"
Blowdown valve
Flange DN25
Safety valve
Flange DN32
Condensate safety valve
Internal thread 1/2"
Condensate steam line
Internal thread 1/2"
Tank overflow / drain
External thread G3/4"
Tank condensate inlet
Internal thread G1/2"
Flash steam
Internal thread G3/4"

Compressed air

Compressed air min.(bar(g))
5.5
Compressed air max.(bar(g))
10.0

Dimensions & emissions

Width(mm)
2,400
Height(mm)
1,850
Length(mm)
1,000
Weight(kg)
970
Sound pressure level(dB(A))
63
CD45K-DR-H-10 detail page Data sheet PDF
CD54K-DR-H-10
  • Steam output 216.0 kg/h
  • Pressure max. 10.0 bar(g)
  • Heating output 3× 54 kW

Performance

Steam output(kg/h)
216.0
Heat output(kcal/h)
143,486
Working pressure min.(bar(g))
1.0
Working pressure max.(bar(g))
10.0
Max. operating pressure(bar(g))
11.5
Max. steam temperature(°C)
184

Electrical ratings

Operating voltage(V)
400
Frequency(Hz)
50
Phases
3+PE
Heating output(kW)
3× 54.0
Heating element arrangement
3x
Total connected load(kW)
168.0
Control voltage(V DC)
24
Total rated current(A)
3× 81
Fusing (site-supplied)(A)
3× 100
Minimum cross-section(mm²)
3x 4x35,0

Mechanical connections

Steam line
Flange DN20
Water inlet
External thread R1/2"
Blowdown valve
Flange DN25
Safety valve
Flange DN32
Condensate safety valve
Internal thread 1/2"
Condensate steam line
Internal thread 1/2"
Tank overflow / drain
External thread G3/4"
Tank condensate inlet
Internal thread G1/2"
Flash steam
Internal thread G3/4"

Compressed air

Compressed air min.(bar(g))
5.5
Compressed air max.(bar(g))
10.0

Dimensions & emissions

Width(mm)
2,400
Height(mm)
1,850
Length(mm)
1,000
Weight(kg)
970
Sound pressure level(dB(A))
63
CD54K-DR-H-10 detail page Data sheet PDF
CD63K-DR-H-10
  • Steam output 252.0 kg/h
  • Pressure max. 10.0 bar(g)
  • Heating output 3× 63 kW

Performance

Steam output(kg/h)
252.0
Heat output(kcal/h)
167,401
Working pressure min.(bar(g))
1.0
Working pressure max.(bar(g))
10.0
Max. operating pressure(bar(g))
11.5
Max. steam temperature(°C)
184

Electrical ratings

Operating voltage(V)
400
Frequency(Hz)
50
Phases
3+PE
Heating output(kW)
3× 63.0
Heating element arrangement
3x
Total connected load(kW)
195.0
Control voltage(V DC)
24
Total rated current(A)
3× 93
Fusing (site-supplied)(A)
3× 100
Minimum cross-section(mm²)
3x 4x35,0

Mechanical connections

Steam line
Flange DN25
Water inlet
External thread R1/2"
Blowdown valve
Flange DN25
Safety valve
Flange DN32
Condensate safety valve
Internal thread 1/2"
Condensate steam line
Internal thread 1/2"
Tank overflow / drain
External thread G3/4"
Tank condensate inlet
Internal thread G1/2"
Flash steam
Internal thread G3/4"

Compressed air

Compressed air min.(bar(g))
5.5
Compressed air max.(bar(g))
10.0

Dimensions & emissions

Width(mm)
2,400
Height(mm)
1,850
Length(mm)
1,000
Weight(kg)
970
Sound pressure level(dB(A))
63
CD63K-DR-H-10 detail page Data sheet PDF
CD72K-DR-H-10
  • Steam output 288.0 kg/h
  • Pressure max. 10.0 bar(g)
  • Heating output 3× 72 kW

Performance

Steam output(kg/h)
288.0
Heat output(kcal/h)
191,315
Working pressure min.(bar(g))
1.0
Working pressure max.(bar(g))
10.0
Max. operating pressure(bar(g))
11.5
Max. steam temperature(°C)
184

Electrical ratings

Operating voltage(V)
400
Frequency(Hz)
50
Phases
3+PE
Heating output(kW)
3× 72.0
Heating element arrangement
3x
Total connected load(kW)
222.0
Control voltage(V DC)
24
Total rated current(A)
3× 107
Fusing (site-supplied)(A)
3× 125
Minimum cross-section(mm²)
3x 4x50,0

Mechanical connections

Steam line
Flange DN25
Water inlet
External thread R1/2"
Blowdown valve
Flange DN25
Safety valve
Flange DN32
Condensate safety valve
Internal thread 1/2"
Condensate steam line
Internal thread 1/2"
Tank overflow / drain
External thread G3/4"
Tank condensate inlet
Internal thread G1/2"
Flash steam
Internal thread G3/4"

Compressed air

Compressed air min.(bar(g))
5.5
Compressed air max.(bar(g))
10.0

Dimensions & emissions

Width(mm)
2,400
Height(mm)
1,850
Length(mm)
1,000
Weight(kg)
970
Sound pressure level(dB(A))
63
CD72K-DR-H-10 detail page Data sheet PDF

Frequently asked questions about this series

Can the CD series also be fed with demineralised water?

Yes, we even recommend using demineralised water, as all steam- and water-carrying components are already made of stainless steel.

What is the minimum inlet pressure required for the feedwater line?

All systems in this series have a feedwater pump that delivers the feedwater into the boiler. An inlet pressure of approximately 1.0 bar(g) is therefore sufficient. Please note that the feedwater pump is not self-priming.

Does the system have an automatic blowdown function?

Yes, all systems in this series have a pneumatically (compressed air) controlled automatic blowdown. It prevents deposits on the boiler floor by briefly opening the bottom valve at regular intervals (usually once an hour). The interval can be adjusted to suit the feedwater quality.

Which pressure ratings can be run?

The pressure rating can be freely selected — on the 5 bar variants from 1.0 to 5.0 bar(g), on the 10 bar variants from 1.0 to 10.0 bar(g).

Can the heating output be reduced, e.g. where the available connected load is limited?

Yes, by switching off individual heating elements. For example, a CD72S-E-5 (72 kW) becomes a CD36S-E-5 (36 kW) when 4 of the 8 heating elements are switched off. We are happy to equip the system with an optional selector switch, allowing you to set up to three different heating levels.

What should be observed when connecting the safety valve line?

The safety valve line should always be routed to the open air without pressure. Make sure that the outlet is positioned so that nobody is put at risk if the safety valve releases unexpectedly.

Non-binding consultation on CDK-DR-H-10