Electric Steam Generators
Model
CDK-DR-H-5
CDK-DR-H — Compact Steam Generator from DINO, up to 5.0 bar(g) working pressure, 144.0–288.0 kg/h steam output. Electrically heated, Made in Germany.
Capacity class
5 variants
→ swipe for more classes
- Steam output
- —kg/h
- Pressure max.
- —bar(g)
- Heating output
- —kW
Equipment
2 variants
Purchase or rental *
Please choose purchase or rental.
Options (0 of 4)
Technical data
This series is available in 5 capacity stages, depending on the required steam volume or available connected load.
Series data sheet (PDF, all 5 capacity classes) CD36K-DR-H-5 active - Steam output 144.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 36 kW
- Steam output 144.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 36 kW
Performance
- Steam output(kg/h)
- 144.0
- Heat output(kcal/h)
- 94,816
- Working pressure min.(bar(g))
- 1.0
- Working pressure max.(bar(g))
- 5.0
- Max. operating pressure(bar(g))
- 5.8
- Max. steam temperature(°C)
- 158.8
Electrical ratings
- Operating voltage(V)
- 400
- Frequency(Hz)
- 50
- Phases
- 3+PE
- Heating output(kW)
- 3× 36.0
- Heating element arrangement
- 3x
- Total connected load(kW)
- 111.0
- Control voltage(V DC)
- 24
- Total rated current(A)
- 3× 54
- Fusing (site-supplied)(A)
- 3× 63
- Minimum cross-section(mm²)
- 3x 4x25,0
Mechanical connections
- Steam line
- Flange DN25
- Water inlet
- External thread R1/2"
- Blowdown valve
- Flange DN25
- Safety valve
- Flange DN32
- Condensate safety valve
- Internal thread 1/2"
- Condensate steam line
- Internal thread 1/2"
- Tank overflow / drain
- External thread G3/4"
- Tank condensate inlet
- Internal thread G1/2"
- Flash steam
- Internal thread G3/4"
Compressed air
- Compressed air min.(bar(g))
- 5.5
- Compressed air max.(bar(g))
- 10.0
Dimensions & emissions
- Width(mm)
- 2,400
- Height(mm)
- 1,850
- Length(mm)
- 1,000
- Weight(kg)
- 970
- Sound pressure level(dB(A))
- 63
CD45K-DR-H-5 - Steam output 180.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 45 kW
- Steam output 180.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 45 kW
Performance
- Steam output(kg/h)
- 180.0
- Heat output(kcal/h)
- 118,519
- Working pressure min.(bar(g))
- 1.0
- Working pressure max.(bar(g))
- 5.0
- Max. operating pressure(bar(g))
- 5.8
- Max. steam temperature(°C)
- 158.8
Electrical ratings
- Operating voltage(V)
- 400
- Frequency(Hz)
- 50
- Phases
- 3+PE
- Heating output(kW)
- 3× 45.0
- Heating element arrangement
- 3x
- Total connected load(kW)
- 138.0
- Control voltage(V DC)
- 24
- Total rated current(A)
- 3× 67
- Fusing (site-supplied)(A)
- 3× 80
- Minimum cross-section(mm²)
- 3x 4x35,0
Mechanical connections
- Steam line
- Flange DN25
- Water inlet
- External thread R1/2"
- Blowdown valve
- Flange DN25
- Safety valve
- Flange DN32
- Condensate safety valve
- Internal thread 1/2"
- Condensate steam line
- Internal thread 1/2"
- Tank overflow / drain
- External thread G3/4"
- Tank condensate inlet
- Internal thread G1/2"
- Flash steam
- Internal thread G3/4"
Compressed air
- Compressed air min.(bar(g))
- 5.5
- Compressed air max.(bar(g))
- 10.0
Dimensions & emissions
- Width(mm)
- 2,400
- Height(mm)
- 1,850
- Length(mm)
- 1,000
- Weight(kg)
- 970
- Sound pressure level(dB(A))
- 63
CD54K-DR-H-5 - Steam output 216.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 54 kW
- Steam output 216.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 54 kW
Performance
- Steam output(kg/h)
- 216.0
- Heat output(kcal/h)
- 142,223
- Working pressure min.(bar(g))
- 1.0
- Working pressure max.(bar(g))
- 5.0
- Max. operating pressure(bar(g))
- 5.8
- Max. steam temperature(°C)
- 158.8
Electrical ratings
- Operating voltage(V)
- 400
- Frequency(Hz)
- 50
- Phases
- 3+PE
- Heating output(kW)
- 3× 54.0
- Heating element arrangement
- 3x
- Total connected load(kW)
- 165.0
- Control voltage(V DC)
- 24
- Total rated current(A)
- 3× 80
- Fusing (site-supplied)(A)
- 3× 100
- Minimum cross-section(mm²)
- 3x 4x35,0
Mechanical connections
- Steam line
- Flange DN25
- Water inlet
- External thread R1/2"
- Blowdown valve
- Flange DN25
- Safety valve
- Flange DN32
- Condensate safety valve
- Internal thread 1/2"
- Condensate steam line
- Internal thread 1/2"
- Tank overflow / drain
- External thread G3/4"
- Tank condensate inlet
- Internal thread G1/2"
- Flash steam
- Internal thread G3/4"
Compressed air
- Compressed air min.(bar(g))
- 5.5
- Compressed air max.(bar(g))
- 10.0
Dimensions & emissions
- Width(mm)
- 2,400
- Height(mm)
- 1,850
- Length(mm)
- 1,000
- Weight(kg)
- 970
- Sound pressure level(dB(A))
- 63
CD63K-DR-H-5 - Steam output 252.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 63 kW
- Steam output 252.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 63 kW
Performance
- Steam output(kg/h)
- 252.0
- Heat output(kcal/h)
- 165,927
- Working pressure min.(bar(g))
- 1.0
- Working pressure max.(bar(g))
- 5.0
- Max. operating pressure(bar(g))
- 5.8
- Max. steam temperature(°C)
- 158.8
Electrical ratings
- Operating voltage(V)
- 400
- Frequency(Hz)
- 50
- Phases
- 3+PE
- Heating output(kW)
- 3× 63.0
- Heating element arrangement
- 3x
- Total connected load(kW)
- 192.0
- Control voltage(V DC)
- 24
- Total rated current(A)
- 3× 92
- Fusing (site-supplied)(A)
- 3× 100
- Minimum cross-section(mm²)
- 3x 4x35,0
Mechanical connections
- Steam line
- Flange DN32
- Water inlet
- External thread R1/2"
- Blowdown valve
- Flange DN25
- Safety valve
- Flange DN32
- Condensate safety valve
- Internal thread 1/2"
- Condensate steam line
- Internal thread 1/2"
- Tank overflow / drain
- External thread G3/4"
- Tank condensate inlet
- Internal thread G1/2"
- Flash steam
- Internal thread G3/4"
Compressed air
- Compressed air min.(bar(g))
- 5.5
- Compressed air max.(bar(g))
- 10.0
Dimensions & emissions
- Width(mm)
- 2,400
- Height(mm)
- 1,850
- Length(mm)
- 1,000
- Weight(kg)
- 970
- Sound pressure level(dB(A))
- 63
CD72K-DR-H-5 - Steam output 288.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 72 kW
- Steam output 288.0 kg/h
- Pressure max. 5.0 bar(g)
- Heating output 3× 72 kW
Performance
- Steam output(kg/h)
- 288.0
- Heat output(kcal/h)
- 189,631
- Working pressure min.(bar(g))
- 1.0
- Working pressure max.(bar(g))
- 5.0
- Max. operating pressure(bar(g))
- 5.8
- Max. steam temperature(°C)
- 158.8
Electrical ratings
- Operating voltage(V)
- 400
- Frequency(Hz)
- 50
- Phases
- 3+PE
- Heating output(kW)
- 3× 72.0
- Heating element arrangement
- 3x
- Total connected load(kW)
- 219.0
- Control voltage(V DC)
- 24
- Total rated current(A)
- 3× 106
- Fusing (site-supplied)(A)
- 3× 125
- Minimum cross-section(mm²)
- 3x 4x50,0
Mechanical connections
- Steam line
- Flange DN32
- Water inlet
- External thread R1/2"
- Blowdown valve
- Flange DN25
- Safety valve
- Flange DN32
- Condensate safety valve
- Internal thread 1/2"
- Condensate steam line
- Internal thread 1/2"
- Tank overflow / drain
- External thread G3/4"
- Tank condensate inlet
- Internal thread G1/2"
- Flash steam
- Internal thread G3/4"
Compressed air
- Compressed air min.(bar(g))
- 5.5
- Compressed air max.(bar(g))
- 10.0
Dimensions & emissions
- Width(mm)
- 2,400
- Height(mm)
- 1,850
- Length(mm)
- 1,000
- Weight(kg)
- 970
- Sound pressure level(dB(A))
- 63
Frequently asked questions about this series
Can the CD series also be fed with demineralised water?
Yes, we even recommend using demineralised water, as all steam- and water-carrying components are already made of stainless steel.
What is the minimum inlet pressure required for the feedwater line?
All systems in this series have a feedwater pump that delivers the feedwater into the boiler. An inlet pressure of approximately 1.0 bar(g) is therefore sufficient. Please note that the feedwater pump is not self-priming.
Does the system have an automatic blowdown function?
Yes, all systems in this series have a pneumatically (compressed air) controlled automatic blowdown. It prevents deposits on the boiler floor by briefly opening the bottom valve at regular intervals (usually once an hour). The interval can be adjusted to suit the feedwater quality.
Which pressure ratings can be run?
The pressure rating can be freely selected — on the 5 bar variants from 1.0 to 5.0 bar(g), on the 10 bar variants from 1.0 to 10.0 bar(g).
Can the heating output be reduced, e.g. where the available connected load is limited?
Yes, by switching off individual heating elements. For example, a CD72S-E-5 (72 kW) becomes a CD36S-E-5 (36 kW) when 4 of the 8 heating elements are switched off. We are happy to equip the system with an optional selector switch, allowing you to set up to three different heating levels.
What should be observed when connecting the safety valve line?
The safety valve line should always be routed to the open air without pressure. Make sure that the outlet is positioned so that nobody is put at risk if the safety valve releases unexpectedly.
Matching accessories for CDK-DR-H-5
These products are frequently used together with the CDK-DR-H-5 — for optimal water quality and safe operation.
Water Treatment
Twin-column softening system
Twin-column softening systems (DKC1 series) with two modules for continuous water softening: while one module regenerates, the other take…
Learn more
Blowdown Vessel
Blowdown vessel
The blowdown vessel cools hot blowdown and condensate water down to a permissible discharge temperature by admixing cold water.
Learn moreNon-binding consultation on CDK-DR-H-5
Our specialists in Bremen configure the system to match your requirements and advise you on the accessories you need.